How to identified a I20 volume
From Wiki-UX.info
The following document clarifies the meaning of the "I20" identification string on an "ioscan" output. HP 9000 N and L class servers offers an optional 4Si 4-Channel Ultra2 SCSI Raid adaptor (A5856A I2O RAID ). When configure and installed. the volumes recieve the identification string "I20".
For example an "ioscan -fnkC disk" will present the 4Si RAID physical volumes as:
# ioscan -fn
Class I H/W Path Driver S/W State H/W Type Description
====================================================================================
...
ba 5 0/4 lba CLAIMED BUS_NEXUS Local PCI-X Bus Adapter (122e)
slot 4 0/4/1 pci_slot CLAIMED SLOT PCI Slot
escsi_ctlr 0 0/4/1/0 sasd CLAIMED INTERFACE HP PCI/PCI-X SAS MPT Adapter
/dev/sasd0
ext_bus 2 0/4/1/0.0.0 sasd_vbus CLAIMED INTERFACE SAS Device Interface
target 9 0/4/1/0.0.0.0 tgt CLAIMED DEVICE
disk 2 0/4/1/0.0.0.0.0 sdisk CLAIMED DEVICE HP IR Volume
/dev/dsk/c2t0d0 /dev/dsk/c2t0d0s2 /dev/rdsk/c2t0d0 /dev/rdsk/c2t0d0s2
/dev/dsk/c2t0d0s1 /dev/dsk/c2t0d0s3 /dev/rdsk/c2t0d0s1 /dev/rdsk/c2t0d0s3
...
To verified the configuration of the 4Si controller and it's logical and physical devices, use the "irdiag" command. For example:
# irdiag -i
Adapter Hardware Path: 0/7/0/1
Device File: /dev/iop0
Product ID: 467
Firmware Version: U.01.06
Number of Logical Drives Configured: 3
Maximum Concurrent Commands Supported: 254
Maximum Targets Supported per Channel: 16
Number of Channels: 4
Flush Interval: 4
Rebuild Rate: 30
Dram Size (Mb): 128
Battery Pack: Present
Battery Status: Charging Completed
Battery Temperature: Good
Battery Voltage: Good
# irdiag -v
******************** Internal RAID Adapter 0/7/0/1 ********************
PowerFail Safeguard = ENABLED
Disk Spin Up = AUTOMATIC
Rebuild Rate = 30%
Firmware Version = U.01.06
DRAM Size = 128 MB
Device File = /dev/iop1
Hardware Path = 0/7/0/1
Adapter Type = 467
Speaker = DISABLED
Battery Pack = CONNECTED
Battery Status = CHARGING COMPLETED
Battery Temperature = GOOD
Battery Voltage = GOOD
Battery Charge Counter = 1
Configuration Saves = 6
Firmware Downloads = 2
Initiator ID = 7
----------Channel 0----------
State = ACTIVE
Termination = WIDE
SCSI Transfer Rate = ULTRA-2
SCSI Devices Attached:
Ch ID Type Capacity Vendor/Product/Revision Status
0 0 DISK 8681 MB IBM DMVS09D HP07 HOTSPARE
0 1 DISK 8681 MB IBM DMVS09D HP07 ONLINE
0 2 DISK 8681 MB IBM DMVS09D HP07 ONLINE
0 3 DISK 8681 MB IBM DMVS09D HP07 ONLINE
0 8 DISK 8681 MB IBM DMVS09D HP07 ONLINE
0 9 DISK 8681 MB IBM DMVS09D HP07 ONLINE
0 10 DISK 8681 MB IBM DMVS09D HP07 ONLINE
0 11 DISK 8681 MB IBM DMVS09D HP07 READY
0 12 DISK 8681 MB IBM DMVS09D HP07 READY
0 13 DISK 8681 MB IBM DMVS09D HP07 READY
0 14 SES N/A HP A5272A HP04
----------Channel 1----------
State = ACTIVE
Termination = WIDE
SCSI Transfer Rate = ULTRA-2
SCSI Devices Attached:
None Detected
----------Channel 2----------
State = ACTIVE
Termination = WIDE
SCSI Transfer Rate = ULTRA-2
SCSI Devices Attached:
None Detected
----------Channel 3----------
State = ACTIVE
Termination = WIDE
SCSI Transfer Rate = ULTRA-2
SCSI Devices Attached:
None Detected
----------------------LOGICAL DRIVES SUMMARY--------------------
LD RAID Size #Stripes StrpSz Drive-State
0 1 8682MB(8.5GB) 2 64KB OPTIMAL
1 1 8682MB(8.5GB) 2 64KB OPTIMAL
2 1 8682MB(8.5GB) 2 64KB OPTIMAL
--------------------------Logical Drive 0-------------------------
RAID LEVEL = 1
Size = 8682MB (8.5GB)
StripeSize = 64KB
Write Policy = WRTHRU
Read Policy = ADAPTIVE
Cache Policy = Cached IO
#Stripes = 2
State = OPTIMAL
Spanned = NO
#Spans = 1
Disks in Span 0 :
Ch ID Type Capacity Vendor/Product/Revision Status
0 1 DISK 8681 MB IBM DMVS09D HP07 ONLINE
0 2 DISK 8681 MB IBM DMVS09D HP07 ONLINE
--------------------------Logical Drive 1-------------------------
RAID LEVEL = 1
Size = 8682MB (8.5GB)
StripeSize = 64KB
Write Policy = WRTHRU
Read Policy = ADAPTIVE
Cache Policy = Cached IO
#Stripes = 2
State = OPTIMAL
Spanned = NO
#Spans = 1
Disks in Span 0 :
Ch ID Type Capacity Vendor/Product/Revision Statu
0 3 DISK 8681 MB IBM DMVS09D HP07 ONLINE
0 8 DISK 8681 MB IBM DMVS09D HP07 ONLINE
--------------------------Logical Drive 2-------------------------
RAID LEVEL = 1
Size = 8682MB (8.5GB)
StripeSize = 64KB
Write Policy = WRTHRU
Read Policy = ADAPTIVE
Cache Policy = Cached IO
#Stripes = 2
State = OPTIMAL
Spanned = NO
#Spans = 1
Disks in Span 0 :
Ch ID Type Capacity Vendor/Product/Revision Status
0 9 DISK 8681 MB IBM DMVS09D HP07 ONLINE
0 10 DISK 8681 MB IBM DMVS09D HP07 ONLINE
-----------------SCSI Device 0:0----------------
Channel = 0
Target = 0
Block Size = 512 Bytes
Device Type = DISK
Capacity = 8681 MB
Vendor ID = IBM
Product ID = DMVS09D
Revision = HP07
SCSI Standard = SCSI-3
Media Errors = 0
Other Errors = 0
State = HOTSPARE
Tag Depth = 0
SyncNegotiation = 0
-----------------SCSI Device 0:1----------------
Channel = 0
Target = 1
Block Size = 512 Bytes
Device Type = DISK
Capacity = 8681 MB
Vendor ID = IBM
Product ID = DMVS09D
Revision = HP07
SCSI Standard = SCSI-3
Media Errors = 0
Other Errors = 0
State = ONLINE
Tag Depth = 0
SyncNegotiation = 0
Part of Logical Drive 0
-----------------SCSI Device 0:2----------------
Channel = 0
Target = 2
Block Size = 512 Bytes
Device Type = DISK
Capacity = 8681 MB
Vendor ID = IBM
Product ID = DMVS09D
Revision = HP07
SCSI Standard = SCSI-3
Media Errors = 0
Other Errors = 0
State = ONLINE
Tag Depth = 0
SyncNegotiation = 0
Part of Logical Drive 0
.
.
.
-----------------SCSI Device 0:14----------------
Channel = 0
Target = 14
Device Type = SES
Vendor ID = HP
Product ID = A5272A
Revision = HP04
SCSI Standard = SCSI-2
Tag Depth = 0
SyncNegotiation = 0
-----------Enclosure at Channel 0:Target 14-------------
Enclosure is in SES mode
ENCLOSURE CONFIGURATION
Enclosure Vendor ID = HP
Product ID = A5272A
Product Revision Level = HP04
Vendor Specific Enclosure Information = Ultra2 SCSI High Availability Storage
System 1010D
Monitored elements: Up to 10 Disk Device
Up to 2 Power Supply
Up to 2 Fan
Up to 4 Temperature
Up to 1 Audible Alarm
Up to 2 Enclosure Services Controller
Up to 2 Port Transceiver
Up to 6 Voltage Sensor
ENCLOSURE STATUS
Critical condition detected (see below)
Device 0 Okay
SCSI TID: 0
Device 1 Okay
SCSI TID: 8
Device 2 Okay
SCSI TID: 1
Device 3 Ok
SCSI TID: 9
Device 4 Okay
SCSI TID: 2
Device 5 Ok
SCSI TID: 10
Device 6 Okay
SCSI TID: 3
Device 7 Okay 4
SCSI TID: 11
Device 8 Okay 2
SCSI TID: 13
Device 9 Okay 6
SCSI TID: 12
Power supply 0 Critical
Failed LED on
Power supply 1 Okay
Cooling element 0 Okay
Fan speed: intermediate
Cooling element 1 Okay
Fan speed: intermediate
Temperature sensor 0 Okay
Temperature = 25 Celsius
Temperature sensor 1 Okay
Temperature = 26 Celsius
Temperature sensor 2 Not installed
Temperature sensor 3 Not installed
Unspecified 0 Okay
Enclosure controller 0 Okay
Active controller
Enclosure controller 1 Not installed
SCSI port/transceiver 0 Okay
SCSI port/transceiver 1 Not installed
Voltage sensor 0 Okay
Voltage = 338 millivolts
Voltage sensor 1 Okay
Voltage = 516 millivolts
Voltage sensor 2 Okay
Voltage = 1224 millivolts
Voltage sensor 3 Not installed
Voltage sensor 4 Not installed
Voltage sensor 5 Not installed
.
.
.
Ch0 Ch1 Ch2 Ch3
ID
0 HSP - - -
1 ONL - - -
2 ONL - - -
3 ONL - - -
4 - - - -
5 - - - -
6 - - - -
7 - - - -
8 ONL - - -
9 ONL - - -
10 ONL - - -
11 RDY - - -
12 RDY - - -
13 RDY - - -
14 - - - -
15 - - - -
where RDY = READY
ONL = ONLINE
HSP = HOTSPARE
FAIL = FAILED
RBLD = REBUILD
UNKN = UNKNOWN
Reference
- HP A5856A RAID 4Si PCI 4-Channel Ultra2 SCSI Controller - Installation and Administration Guide